Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 13(1): e0191885, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29377922

RESUMO

BACKGROUND: Filling the lung with dense liquid perfluorocarbons during total liquid ventilation (TLV) might compress the myocardium, a plausible explanation for the instability occasionally reported with this technique. Our objective is to assess the impacts of TLV on the cardiovascular system, particularly left ventricular diastolic function, in an ovine model of neonatal respiratory distress syndrome. METHOD: Eight newborns lambs, 3.0 ± 0.4 days (3.2 ± 0.3kg) were used in this crossover experimental study. Animals were intubated, anesthetized and paralyzed. Catheters were inserted in the femoral and pulmonary arteries. A high-fidelity pressure catheter was inserted into the left ventricle. Surfactant deficiency was induced by repeated lung lavages with normal saline. TLV was then conducted for 2 hours using a liquid ventilator prototype. Thoracic echocardiography and cardiac output assessment by thermodilution were performed before and during TLV. RESULTS: Left ventricular end diastolic pressure (LVEDP) (9.3 ± 2.1 vs. 9.2 ± 2.4mmHg, p = 0.89) and dimension (1.90 ± 0.09 vs. 1.86 ± 0.12cm, p = 0.72), negative dP/dt (-2589 ± 691 vs. -3115 ± 866mmHg/s, p = 0.50) and cardiac output (436 ± 28 vs. 481 ± 59ml/kg/min, p = 0.26) were not affected by TLV initiation. Left ventricular relaxation time constant (tau) slightly increased from 21.5 ± 3.3 to 24.9 ± 3.7ms (p = 0.03). Mean arterial systemic (48 ± 6 vs. 53 ± 7mmHg, p = 0.38) and pulmonary pressures (31.3 ± 2.5 vs. 30.4 ± 2.3mmHg, p = 0.61) were stable. As expected, the inspiratory phase of liquid cycling exhibited a small but significant effect on most variables (i.e. central venous pressure +2.6 ± 0.5mmHg, p = 0.001; LVEDP +1.18 ± 0.12mmHg, p<0.001). CONCLUSIONS: TLV was well tolerated in our neonatal lamb model of severe respiratory distress syndrome and had limited impact on left ventricle diastolic function when compared to conventional mechanical ventilation.


Assuntos
Diástole , Modelos Animais de Doenças , Ventilação Líquida/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Função Ventricular Esquerda , Animais , Animais Recém-Nascidos , Fluorocarbonos/farmacocinética , Hidrocarbonetos Bromados , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Ovinos
2.
IEEE Trans Biomed Eng ; 64(12): 2760-2770, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28237918

RESUMO

GOAL: Recent preclinical studies have shown that therapeutic hypothermia induced in less than 30 min by total liquid ventilation (TLV) strongly improves the survival rate after cardiac arrest. When the lung is ventilated with a breathable perfluorocarbon liquid, the inspired perfluorocarbon allows us to control efficiently the cooling process of the organs. While TLV can rapidly cool animals, the cooling speed in humans remains unknown. The objective is to predict the efficiency and safety of ultrafast cooling by TLV in adult humans. METHODS: It is based on a previously published thermal model of ovines in TLV and the design of a direct optimal controller to compute the inspired perfluorocarbon temperature profile. The experimental results in an adult sheep are presented. The thermal model of sheep is subsequently projected to a human model to simulate the optimal hypothermia induction and its sensitivity to physiological parameter uncertainties. RESULTS: The results in the sheep showed that the computed inspired perfluorocarbon temperature command can avoid arterial temperature undershoot. The projection to humans revealed that mild hypothermia should be ultrafast (reached in fewer than 3 min (-72 °C/h) for the brain and 20 min (-10 °C/h) for the entire body). CONCLUSION: The projection to human model allows concluding that therapeutic hypothermia induction by TLV can be ultrafast and safe. SIGNIFICANCE: This study is the first to simulate ultrafast cooling by TLV in a human model and is a strong motivation to translate TLV to humans to improve the quality of life of postcardiac arrest patients.


Assuntos
Fluorocarbonos , Hipotermia Induzida/métodos , Ventilação Líquida/métodos , Adulto , Animais , Encéfalo/fisiologia , Simulação por Computador , Fluorocarbonos/administração & dosagem , Fluorocarbonos/uso terapêutico , Parada Cardíaca/terapia , Humanos , Pulmão/fisiologia , Modelos Biológicos , Ovinos , Temperatura
3.
IEEE Trans Biomed Eng ; 63(7): 1483-91, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26552070

RESUMO

BACKGROUND: Total liquid ventilation (TLV) consists in filling the lungs with a perfluorocarbon (PFC) and using a liquid ventilator to ensure a tidal volume of oxygenated, CO 2 -free and temperature-controlled PFC. Having a much higher thermal capacity than air, liquid PFCs assume that the filled lungs become an efficient heat exchanger with pulmonary circulation. OBJECTIVE: The objective of the present study was the development and validation of a parametric lumped thermal model of a subject in TLV. METHODS: The lungs were modeled as one compartment in which the control volume varied as a function of the tidal volume. The heat transfer in the body was modeled as seven parallel compartments representing organs and tissues. The thermal model of the lungs and body was validated with two groups of lambs of different ages and weights (newborn and juvenile) undergoing an ultrafast mild therapeutic hypothermia induction by TLV. RESULTS: The model error on all animals yielded a small mean error of -0.1 ±0.4  (°)C for the femoral artery and 0.0 ±0.1   (°)C for the pulmonary artery. CONCLUSION: The resulting experimental validation attests that the model provided an accurate estimation of the systemic arterial temperature and the venous return temperature. SIGNIFICANCE: This comprehensive thermal model of the lungs and body has the advantage of closely modeling the rapid thermal dynamics in TLV. The model can explain how the time to achieve mild hypothermia between newborn and juvenile lambs remained similar despite of highly different physiological and ventilatory parameters. The strength of the model is its strong relationship with the physiological parameters of the subjects, which suggests its suitability for projection to humans.


Assuntos
Hipotermia Induzida/métodos , Ventilação Líquida/métodos , Modelos Biológicos , Animais , Animais Recém-Nascidos , Temperatura Corporal/fisiologia , Pulmão/fisiologia , Reprodutibilidade dos Testes , Ovinos
4.
IEEE Trans Biomed Eng ; 61(12): 2859-68, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24960422

RESUMO

In total liquid ventilation (TLV), the lungs are filled with a breathable liquid perfluorocarbon (PFC) while a liquid ventilator ensures proper gas exchange by renewal of a tidal volume of oxygenated and temperature-controlled PFC. Given the rapid changes in core body temperature generated by TLV using the lung has a heat exchanger, it is crucial to have accurate and reliable core body temperature monitoring and control. This study presents the design of a virtual lung temperature sensor to control core temperature. In the first step, the virtual sensor, using expired PFC to estimate lung temperature noninvasively, was validated both in vitro and in vivo. The virtual lung temperature was then used to rapidly and automatically control core temperature. Experimentations were performed using the Inolivent-5.0 liquid ventilator with a feedback controller to modulate inspired PFC temperature thereby controlling lung temperature. The in vivo experimental protocol was conducted on seven newborn lambs instrumented with temperature sensors at the femoral artery, pulmonary artery, oesophagus, right ear drum, and rectum. After stabilization in conventional mechanical ventilation, TLV was initiated with fast hypothermia induction, followed by slow posthypothermic rewarming for 1 h, then by fast rewarming to normothermia and finally a second fast hypothermia induction phase. Results showed that the virtual lung temperature was able to provide an accurate estimation of systemic arterial temperature. Results also demonstrate that TLV can precisely control core body temperature and can be favorably compared to extracorporeal circulation in terms of speed.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Ventilação Líquida/instrumentação , Ventilação Líquida/métodos , Termografia/instrumentação , Termografia/métodos , Interface Usuário-Computador , Ar Condicionado/instrumentação , Ar Condicionado/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Retroalimentação Fisiológica/fisiologia , Calefação/instrumentação , Calefação/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...